DENTAL
ULTRAFLEX BENDABLE ELECTRODES
Electrodes
also available in Rigid style.
|
|
Dental
UltraFlex
Bendable Electrodes
|
|
Download
PDF
|
|
|
|
| INCISION:
All below have fine .010 tungsten surgical wire for precise
incision with minimum tissue alteration. |
| UF-F1 |
| Adjustotip
variable length, angled shaft (adjustable depth, especially
effective posteriorly ) |
|
|
|
| UF-F10 |
| 6mm
wire, straight shaft, anterior specific |
|
|
|
| UF-F11 |
|
6mm wire, angled shaft |
|
|
|
| UF-F13 |
|
6mm wire, shaft reversed for posterior access |
|
|
|
| UF-C51 |
|
1,5 mm ball, angled shaft (for small area forced coagulation) |
|
|
|
| UF-C52 |
| 3mm
ball, angled shaft (for medium area forced coagulation) |
|
|
|
| UF-C53 |
|
13mm .025 wire, straight shaft (for small spot forced
coagulation, anterior specific) |
|
|
|
| UF-C54 |
13mm .025 wire, bent to 80 degrees @ 10mm, straight
shaft
(for small spot forced coagulation) |
|
|
|
| UF-C15 |
|
.020 wire, right angle with straight shaft (for
intraproximal spot forced coagulation, has thin insulation,
especially recommended where metallic amalgams are present) |
|
|
|
|
|
|
FULGURATION:
NOTE: the UF-C52 is suitable for soft coagulation ( with the
ME600 fulguration adaptor only ) of
enucleated cysts or creating a 1-1.5 mm coagulum over large
areas for healing by second intent. |
| UF-SN61 |
|
angled, small point, stainless steel (for very small spot
soft coagulation) |
|
|
|
| UF-SN62 |
| angled,
medium spot, brass (for spot soft coagulation) |
|
|
|
| R-SN62 |
|
rigid stainless steel version of above |
|
|
|
|
| PERIODONTAL:
NOTE: UF-L19, UF-L22, UF-L23, and UF-L29 are also useful for
shallow periodontal treatment. |
| UF-L24 |
|
1,5mm X 15mm loop, 45 degree shaft, perpendicular loop |
|
|
|
| UF-L25 |
| 1,5mm
X 15mm loop, 45 degree shaft, parallel loop |
|
|
|
|
|
| GINGIVAL
TROUGHING: These electrodes are made of fine .010
surgical tungsten wire for minimal tissue alteration. They are
also excellent for fine shaving and tissue tag removal. Those
not specific to anterior access are suitable for both anterior
and posterior, also, interproximal where access permits. NOTE:
the UF-SN61 and R-SN62 stainless steel fulguration electrodes
are also suitable for narrow, shallow troughing ( UF-SN61 is
.5mm X 3mm and R-SN62 is 2mm X 6mm ). Deeper cuts with these
electrodes may create some circatrix, however. The UF-SN61 fits
easily interproximally. Due to the larger surface area, the
UF-SN61 and R-SN61 will enhance concurrent hemostasis, when
required, in comparison to the loops. |
| UF-L16 |
|
J shaped, 1mm X 2.3mm, right hook, angled shaft (anterior specific, V shaped trough) |
|
|
|
| UF-L17 |
| J shaped, 1mm X 2.3mm, left hook, angled shaft (anterior specific, V shaped trough) |
|
|
|
| UF-L18 |
| 1.5mm
X 5mm loop, straight shaft (anterior, U shaped trough) |
|
|
|
| UF-L19 |
| 1.5mm
X 7mm loop, 45 degree, straight shaft, loop perpendicular
to shaft (U shaped trough) |
|
|
|
| UF-L21 |
|
1mm X 6mm loop, 45 @ 4mm parallel to shaft, shaft bent @ 80 (posterior specific, U shaped trough) |
|
|
|
| UF-L22 |
| 1.5mm X 8mm loop, 45 degree shaft, loop parallel to shaft (U shaped trough) |
|
|
|
| UF-L23 |
|
1.5mm X 8mm loop, 45 degree shaft, loop perpendicular to shaft
(U shaped trough) |
|
|
|
| UF-L29 |
|
1.5mm X 7mm loop, 45 degree, straight shaft, loop parallel to shaft
(U shaped trough) |
|
|
|
| UF-L38 |
| 2mm X 7mm loop, straight shaft
(anterior specific, U shaped trough) |
|
|
|
| UF-L39 |
| 2mm X 7mm loop, 45 degree, straight shaft, loop parallel to shaft
(U shaped trough) |
|
|
|
| UF-L41 |
|
2mm X 7mm loop, 90 degree shaft, loop parallel to shaft (U shaped trough) |
|
|
|
|
| EXCISION:
All below have fine .010 surgical tungsten wire for precise
cuts with minimum tissue alteration. |
| UF-F12 |
| 14mm wire, straight shaft, wire bent 80 degrees @ 7mm (elliptical biopsy, incision, planing) |
|
|
|
| UF-L32 |
|
3,5mm round loop (planning, sculpting, or biopsy) |
|
|
|
| UF-L33 |
|
5mm round loop (planning, sculpting, especially sulcus, or biopsy) |
|
|
|
| UF-L34 |
| 10mm round loop (planning, sculpting, or biopsy, also effective for frenectomy) |
|
|
|
| UF-L45 |
|
13mm round loop (planning, large biopsy, also effective for frenectomy) |
|
|
|
| UF-L35 |
| 3mm X 7mm oval loop, straight (pontic recess sculpting, concave sculpting, biopsy) |
|
|
|
| UF-L36 |
|
4mm X 10mm oval loop, straight (pontic recess sculpting, concave sculpting, biopsy) |
|
|
|
| UF-L37 |
|
3mm X 7mm oval loop, angled as above (also effective for palatal stripping) |
|
|
|
| UF-L42 |
|
4mm X 7mm oval loop, angled as above (also effective for palatal stripping) |
|
|
|
| UF-L31 |
|
5mm X 5mm square loop, straight (biopsy, interseptal papilla, donor graft harvesting) |
|
|
|
| UF-L26 |
|
4mm x 4mm triangle loop, straight (ridge trim, tuberosity reduction, shallow angle concave sculpting, donor graft harvesting) |
|
|
|
|
UF-F1,
UF-11 incision, crown eleongation, composite exposure,
subgingival carie exposure
UF-L22 pupotomy, remove tissue tags, gigivectomy
UF-L34 hyperplastic tissue planning, frenectomy
UF-L35 gingival contouring, palatal stripping, crown lengthening
UF-SN62 spot fulguration, coagulation of pin point exposure
UF-C52 large area coagulation, desensitizing hypersensitive
dentin, bleaching
UF-F13 per UF-F11, except specific to posterior access
UF-C15 interproximal coagulation |
|
UF-F1,
UF-F11 incision, operculectomy, uninterrupted tooth exposure,
cyst enucleation
UF-L35 palatal stripping
UF-L45 large excisional biopsy, hyperplastic tissue reduction
(planing)
UF-C51 1.5mm ball, coagulation
R-C54, R-C55 .025 ss wire, for incision with very
pronounced concurrent hemostasis
UF-SN61 pin point fulguration, dessication of lesions
in situ
UF-SN62 spot fulguration, effective near nutrient foramen
on exposed bone
UF-C15 interproximal coagulation |
|
UF-F1,
UF-F11 incision
UF-F13 incision (posterior specific: reverse angle bend)
UF-F16, UF-F17 shallow troughing (right and left hooks,
V groove)
UF-L19, UF-L29 troughing, fine planing gingiplasty (parallel
and perpendicular, close, U groove)
UF-L32, UF-L33, UF-L34 create sulcus, planning, gingiplasty,
biopsy (3,5mm, 5mm, 10mm loops)
UF-L35, UF-L36 pontic and sulcus sculpture, planning,
gingiplasty (straight shaft oval loop)
UF-L37, UF-L42 as above, also palatal stripping (angled
shaft)
UF-L26 gingiplasty, planning, donor graft harvesting (triangle
loop)
UF-L31 gingiplasty, planning, donor graft harvesting (square
loop)
UF-L22, UF-L23 troughing, planning, gingiplasty, tissue
tags (parallel and perpendicular)
UF-C51, UF-C52 coagulation balls for forced coagulation
UF-C15, UF-C55 spot coagulation (UF-C15 is interproximal
specific)
UF-SN61 fine fulguration, also suitable for fine, shallow
V troughing
UF-SN62 fulguration
R-SN62 as above, but stainless steel suitable for fine,
shallow V troughing |
|
UF-F1,
UF-F11 incision, gingivectomy, frenectomy
UF-L24, UF-L25 gingival curettage, gingivectomy, tissue
tags
UF-L22, UF-L23 shallow gingival curettage
UF-L26, UF-L31 graft donor tissue harvesting
UF-C51 coagulation
UF-SN62 spot fulguration |
|
UF-F1,
UF-F11 incision
UF-L22 pulpotomy
UF-L35, UF-L34 hyperplastic tissue reduction
UF-C51 hemostasis and sterilization of endodontic canals,
intracoronal bleaching
UF-C52 large area coagulation, accelerate bleaching procedures
UF-SN62 spot fulguration, pin point exposure coagulation
|
|
| Care
& Cleaning of Electrodes After Use |
1.
Do not scrub electrodes with a brush or harsh abrasive.
2. To remove blood or tissue prior to autoclaving, place
the electrodes in hydrogen peroxide or in an ultrasonic
cleaner for 1 minute. If carbon deposits cannot be wiped
off, use a fine sandpaper disc to expose the metal.
3. Place the electrodes in an autoclave bag before placing
them in an autoclave. Steam autoclave at 250ºF
(121ºC) for 20 minutes at 15 psi.
4. An aluminum paste may be used to remove oxide. |
|
|
| |
|
Macan Manufacturing Company
Po Box 166, Milton, DE. 19968 - U.S.A
Phone: (302) 645 - 8068
Fax: (302) 645 - 7049
|
|
|
|
|
|
|